Sol: Battery Voltage Software Switch
A software switch can be done within 30 seconds after plugging in a new battery
A software switch can be done within 30 seconds after plugging in a new battery
If the battery you are installing is the same voltage as the one used before. Ignore this step and close this web browser tab.
If you want to change the original setting LiPeFO 3.2V to a NMC 3.7V, you will need to press and hold the power button for 10 seconds. After a 3 seconds you will see a green steady light at the back of the lamp, continue pressing until you see a green/red blinking light. This confirms the switch to 3.7V.
If you want to change the setting NMC 3.7V to the original LiPeFO 3.2V, you will need to press and hold the power button for 10 seconds. After a 3 seconds you will see a green/red steady light at the back of the lamp, continue pressing until you see a green blinking light. This confirms the switch to 3.2V.
At any time you can confirm the Voltage setting. Do this by press/holding the power button for 3 seconds until you see a steady light at the at the back of the lamp.
If the light is green, the setting is 3.2V LiPeFO
If the light is green/red, the setting is 3.7V NMC